How To Calculate Deep Cycle Battery Amp Hours
Reading time 7 minutes
When you are supplying power for an RV, a home solar array or a marine system, understanding how to calculate deep cycle battery amp hours is essential for selecting the right lithium battery. This guide breaks the process down into simple steps so you can size your batteries correctly and achieve dependable, long-term performance in off-grid or mobile setups.

Understanding Amp Hours in a Deep Cycle Battery
Amp hours (Ah) describe how much charge a battery can supply over a given period. For instance, a 100 amp hour deep cycle battery can theoretically deliver 100 amps for one hour, or 5 amps for 20 hours.
Deep cycle batteries are engineered to handle frequent charge and discharge cycles, unlike starter batteries that are intended for short, high-current bursts. Lithium deep cycle batteries, such as LiFePO4, provide clear benefits over lead-acid or AGM batteries: higher efficiency, a much longer cycle life (around 4,000–5,000 cycles vs. 200–500 for lead-acid) and the ability to discharge 90–100% of their capacity with limited wear.
The “C” rating, for example C20 for a 20-hour discharge rate, shows the time frame used for the stated capacity. A 200 amp hour deep cycle battery with a C20 rating will supply 10 amps continuously for 20 hours. Lithium batteries lose very little usable capacity at higher discharge currents, while lead-acid batteries suffer from the Peukert effect and provide less capacity as the load increases.
Accurate amp hour sizing helps you avoid batteries that are too small or unnecessarily large. For example, a group 24 deep cycle battery usually offers around 70–85Ah, while a group 31 deep cycle battery commonly ranges from 100–120Ah. Because these values vary by manufacturer, careful sizing is essential for reliable RV, solar or marine operation.
How to Calculate Amp Hours in a Deep Cycle Battery
To work out the required amp hours for a deep cycle battery, use the basic formula:
Amp Hours (Ah) = Current (Amps) × Time (Hours)
- Example: a 30-amp solar pump running for 5 hours from a lithium battery:
- Current: 30 amps
- Time: 5 hours
- Ah = 30 × 5 = 150Ah
Lithium batteries retain almost their full rated capacity even at higher discharge rates, unlike lead-acid batteries that are affected by the Peukert effect. For small electronic devices, you can convert milliamp-hours (mAh) to amp-hours by dividing by 1,000 (for example, 2,500 mAh = 2.5 Ah).
Check the current draw of your appliance in the user manual, or measure it with a multimeter. As an example, the Vatrer 12V 100Ah LiFePO4 battery is a strong choice for systems that require a steady, consistent power supply.
How to Adjust for the Depth of Discharge in Lithium Batteries
Depth of discharge (DOD) refers to the proportion of a battery’s total capacity that is used during one cycle. Lithium batteries can routinely be discharged to 90–100%, whereas lead-acid batteries are usually limited to 50–80% if you want to maintain their life expectancy. Adjust your required amp hours as follows:
Required Ah = Calculated Ah / DOD
Example: for the 150Ah solar pump load with a 90% DOD:
Required Ah = 150 / 0.9 = 166.67 Ah
In this case, a 200 amp hour deep cycle battery provides a comfortable margin. Vatrer LiFePO4 batteries, which typically deliver 4,000–5,000 cycles at 90% DOD, are particularly well suited to demanding daily-use applications.
Power Your System with the Right Battery Bank
For larger installations, such as solar storage banks or extended RV boondocking, several batteries are often combined into a battery bank, linked in series, parallel or both. The way they are connected determines the overall voltage and amp hours:
- Parallel: Increases total amp hours while voltage stays the same. Example: two 12V 100Ah batteries in parallel give a 12V 200Ah bank.
- Series: Increases voltage while amp hours stay constant. Example: two 12V 100Ah batteries in series form a 24V 100Ah system.
Battery Bank Configurations Reference
| Configuration | Voltage | Amp Hours | Example Use Case |
|---|---|---|---|
| Two 12V 100Ah in Parallel | 12V | 200Ah | RV camping with high daily amp hour demand |
| Two 12V 100Ah in Series | 24V | 100Ah | Solar installation requiring higher DC voltage |
| Four 12V 100Ah (2S2P) | 24V | 200Ah | Power supply for an off-grid cabin |
| Four 12V 100Ah (4S4P) | 48V | 400Ah | Long-distance RV touring or larger solar storage arrays |
The Vatrer 12V 100Ah LiFePO4 battery includes an integrated BMS and can be configured in a 4S4P layout, so whether you are on a multi-day road trip, offshore fishing or running a substantial solar system, the bank can be scaled to match your power needs.
How to Convert Watts to Amp Hours for AC Devices
When you power AC appliances through an inverter, you first convert their power consumption in watts to watt-hours and then to amp hours:
- Watt-Hours = Power (Watts) × Operating Time (Hours)
- Amp Hours = Watt-Hours / Battery Voltage
You also need to consider inverter efficiency (for lithium-based systems this is usually about 92–98%):
- Adjusted Watt-Hours = (Power × Time) / Efficiency
For example, consider a 200-watt RV fridge running for 6 hours from a 12V lithium battery with an inverter that is 95% efficient:
- Watt-Hours = (200 × 6) / 0.95 = 1,263.16 Wh
- Amp Hours = 1,263.16 / 12 = 105.26 Ah
In this scenario, a single 100 amp hour deep cycle battery would not be sufficient; you would instead select a Vatrer 12V 200Ah LiFePO4 battery to supply this load with an appropriate reserve.
Conclusion
Working out deep cycle battery amp hours correctly is fundamental to ensuring a stable power supply for RVs, solar installations and marine systems. By using the calculation steps above, adjusting for DOD and designing your battery bank carefully, you can align your storage capacity with your real-world requirements.
People Also Ask
How Many Amp Hours Are in a Deep Cycle Battery?
The amp hour rating of a deep cycle battery depends on its physical size and chemistry. For lithium batteries, typical ranges include:
- Group 24: Generally around 70–100Ah, suitable for smaller RV or marine systems.
- Group 31: Often 100–120Ah, commonly used for solar storage banks or trolling motors.
- High-capacity units: 200–560Ah, intended for off-grid properties or large motorhomes.
To choose the correct capacity, calculate your amp hour requirement using Ah = Current × Hours and then adjust for the usable DOD range (typically 90–100% for lithium batteries).
For example, a device drawing 50 amps for 4 hours needs 50 × 4 / 0.9 = 222.22 Ah. In this case, a 200 amp hour deep cycle battery or a larger bank would be suitable. Always check the C20 (20-hour) rating to confirm the manufacturer’s specified capacity.
How Does Temperature Affect Deep Cycle Battery Amp Hours?
Temperature has a notable impact on the available amp hours of a lithium battery. Below about 14°F (-10°C), usable capacity may fall by 10–20%, reducing the energy you can draw. At temperatures above 140°F (60°C), efficiency declines and repeated exposure can shorten overall cycle life.
For example, a 100 amp hour deep cycle battery at 0°F might effectively supply only 80–90Ah. Many lithium batteries, including Vatrer 12V LiFePO4 models, incorporate a Battery Management System (BMS) with low-temperature cut-off to prevent damage when charging in very cold conditions.
To compensate, consider average ambient temperatures and increase your calculated capacity by around 10–20% for colder regions. For instance, if you need 150Ah at 0°F, you would plan for 150 / 0.8 = 187.5Ah. In warmer climates, ensure adequate airflow and ventilation to prevent overheating.
Can I Use a Deep Cycle Battery with My Existing Solar Inverter?
Lithium deep cycle batteries are generally compatible with modern solar inverters, provided that voltage and current ratings match. Most inverters are designed for 12V, 24V or 48V DC input, which corresponds to standard lithium battery system voltages.
First, confirm your inverter’s DC input voltage and ensure your battery bank configuration matches it. Next, check that the charge controller or integrated charger supports lithium-specific charging profiles (typically 3.2–3.6V per cell and no equalisation phase).
As an illustration, a 24V inverter powering a 200-watt load for 5 hours requires approximately (200 × 5) / 0.95 / 24 ≈ 43.86 Ah. A single group 31 deep cycle battery rated at 100Ah would comfortably meet this requirement when configured as part of a 24V system. Vatrer batteries are designed with BMS protection to support safe charging in solar applications.
How Do I Choose Between Group 24 and Group 31 Deep Cycle Batteries?
Group 24 batteries usually provide 70–100Ah and are more compact, which suits smaller marine installations, portable systems or light-duty RV use. Group 31 batteries typically offer 100–120Ah and are better suited to higher consumption, such as solar storage banks or powerful trolling motors.
For example, a 300-watt solar array running for 8 hours requires around (300 × 8) / 0.95 / 12 ≈ 210.53 Ah. To meet this demand, you would use a group 31 battery in combination with other batteries, or multiple group 24 units wired in parallel to achieve the total required amp hours.